SWA XLPE/LSF Cable

3 core (6943X) and 4 core (6944X) galvanised SWA (Steel Wire Armoured) Cable. For commercial, industrial or domestic use. BS5467 approval.
6491B Singles Cable

Installation in surface mounted or embedded conduits, or similar closed
systems and for fi xed protected installation in or on lighting fi ttings and
inside appliances, switchgear and control gear particularly for situations
in which low emissions of smoke and acid gas is requred in case of
burning.
Available inGreen/Yellow,Brown,Blue,Grey,Black
Cable approved to BS721
6491X Singles Cable

Installation in surface mounted or embedded conduits or similar closed
systems and for fixed protected installation in or on lighting fi ttings and
inside appliances, switchgear and control gear.
Available in Green/Yellow,Brown,Blue,Grey,Black
Cable approved to BS600
Fire Resistant Cables - FP200 Gold

General
FP200 Gold – Model SpecificationGeneralCables for surface wiring of fire alarm and emergency lighting systems should be of screened construction and sufficiently robust to meet the intended installation condition.
Cables should meet the performance requirements of BS6387 Category CWZ, EN 50200 PH30 & PH60, BS 8434-1 30 minutes, BS EN 60332-1-2, BS EN 50266-2-4, BS EN 61034-2 and produce less than 0.5% acidic gases when tested in accordance with BS EN 50267-2-1.
Voltage rating
The cables shall be rated at 300/500V
Conductors
Conductors shall consist of plain annealed copper and the circuit protective conductor of tinned annealed copper.
Insulation
The insulation shall be of a robust cross-linked mineral filled type complying with BS7655 type EI5.
Core Identification
Cores shall be identified by colours.
Screen
The screen shall consist of a longitudinally applied laminated aluminium tape, of minimum metal thickness 0.075mm, securely bonded to the sheath.
An uninsulated tinned copper circuit protective conductor shall be in contact with the screen.
Sheath
The sheath shall be a robust mineral filled compound complying with BS7655 Type LT
FP200 Gold – Model SpecificationGeneralCables for surface wiring of fire alarm and emergency lighting systems should be of screened construction and sufficiently robust to meet the intended installation condition.
Cables should meet the performance requirements of BS6387 Category CWZ, EN 50200 PH30 & PH60, BS 8434-1 30 minutes, BS EN 60332-1-2, BS EN 50266-2-4, BS EN 61034-2 and produce less than 0.5% acidic gases when tested in accordance with BS EN 50267-2-1.
Voltage rating
The cables shall be rated at 300/500V
Conductors
Conductors shall consist of plain annealed copper and the circuit protective conductor of tinned annealed copper.
Insulation
The insulation shall be of a robust cross-linked mineral filled type complying with BS7655 type EI5.
Core Identification
Cores shall be identified by colours.
Screen
The screen shall consist of a longitudinally applied laminated aluminium tape, of minimum metal thickness 0.075mm, securely bonded to the sheath.
An uninsulated tinned copper circuit protective conductor shall be in contact with the screen.
Sheath
The sheath shall be a robust mineral filled compound complying with BS7655 Type LT
Fire Resistant Cables - FPPlus

General
Cables for fire detection and fire alarm critical signal paths in enhanced application areas, voice alarm systems and emergency lighting systems should be of screened construction and sufficiently robust to meet the intended installation condition.
Cables should meet the performance requirements of BS6387 Category CWZ, EN 50200 PH120, BS 8434-2 120 minutes, BS EN 60332-1-2, BS EN 50266-2-4, BS EN 61034-2 and produce less than 0.5% acidic gases when tested in accordance with BS EN 50267-2-1.
Voltage rating
The cables shall be rated at 300/500V
Conductors
Conductors shall consist of plain annealed copper and the circuit protective conductor of tinned annealed copper.
Insulation
The insulation shall be of a robust cross-linked mineral filled type complying with BS7655 type EI5.
Core Identification
Cores shall be identified by colours.
Screen
The screen shall consist of a longitudinally applied laminated aluminium tape securely bonded to the sheath.
A full size uninsulated tinned copper circuit protective conductor shall be in contact with the screen.
Sheath
The sheath shall be a robust mineral filled compound complying with BS7655 Type LTS3.
Cables for fire detection and fire alarm critical signal paths in enhanced application areas, voice alarm systems and emergency lighting systems should be of screened construction and sufficiently robust to meet the intended installation condition.
Cables should meet the performance requirements of BS6387 Category CWZ, EN 50200 PH120, BS 8434-2 120 minutes, BS EN 60332-1-2, BS EN 50266-2-4, BS EN 61034-2 and produce less than 0.5% acidic gases when tested in accordance with BS EN 50267-2-1.
Voltage rating
The cables shall be rated at 300/500V
Conductors
Conductors shall consist of plain annealed copper and the circuit protective conductor of tinned annealed copper.
Insulation
The insulation shall be of a robust cross-linked mineral filled type complying with BS7655 type EI5.
Core Identification
Cores shall be identified by colours.
Screen
The screen shall consist of a longitudinally applied laminated aluminium tape securely bonded to the sheath.
A full size uninsulated tinned copper circuit protective conductor shall be in contact with the screen.
Sheath
The sheath shall be a robust mineral filled compound complying with BS7655 Type LTS3.
3183y/3184y Flexible Cable

Annealed copper conductors PVC insulated,cores twisted together and oversheathed in PVC type TM2 to form a round cable. Harmonised code no: H05VV-F3
3183b/3184b Flexible Cable LSF

3183B / 3184B multicore LSF or LSZH installation cables are designed for power or control use in panel, conduit and general wiring applications, suitable for use indoors. They have stranded plain copper conductors, low smoke insulation and black or white low smoke sheath as standard. The LSF low smoke and fume or LSZH low smoke zero halogen sheathing minimises the damage caused by fire through emission of smoke and toxic fumes
BT CW1308 Cable

Application
Cables primarily designed for
the interconnection of telephone
equipment which is installed
indoors. In addition these cables
may be used for the interconnection of other communication and control equipment or low level signalling applications.
Standards
CW1308
Conductor
Class 1 solid annealed plain copper
Insulation
PVC (Polyvinyl Chloride)
Separator
PETP (Polyethylene Terephthalate)
Sheath Colour
White or Black
Temperature Rating
0°C to +70°C
Minimum Bending Radius
8 x overall diameter
Cat5e LSF Purple 305mtr

Cat5e solid core shielded twisted pair, is a high performance cable suitable for use with 10Mbps Ethernet, 100Mbps Ethernet and Token Ring.Use this cable for permanent and semi-permanent installations in cabinets, and flood-wiring of buildings. Not suitable for making flexible patch leads. Each cable consists of 8 colour coded 24awg polyethylene insulated conductors. These are twisted together to form 4 pairs. These pairs are wrapped in an aluminium mylar tape screen with a drain wire. Purple overall sheat
Cat5eGrey305mtr

Cat5e solid core shielded twisted pair, is a high performance cable suitable for use with 10Mbps Ethernet, 100Mbps Ethernet and Token Ring.Use this cable for permanent and semi-permanent installations in cabinets, and flood-wiring of buildings. Not suitable for making flexible patch leads. Each cable consists of 8 colour coded 24awg polyethylene insulated conductors. These are twisted together to form 4 pairs. These pairs are wrapped in an aluminium mylar tape screen with a drain wire. Grey overall sheath. LSZH version also available